WhatsApp Us -- Email Us

MTT MS3108 frequency to analog converter with isolated dual output, terminal block DIN-rail type

MTT MS3108 Terminal Block Type Frequency/Analog Converter

SKU: MS3108

The MTT MS3108 converts a pulse train from a flow meter, tachometer, or similar sensor into two independent, isolated DC outputs from one unit, with a choice of AC or DC power supply.

Category: Signal Conditioners, Signal Isolators

Price on request

Send us your requirement and we'll reply with a quotation and technical advice.

⏱ We reply within 1 working day. Specs & downloads ↓
🛠️
Lifetime technical support
🚚
Free domestic shipping
🎯
Calibration services

Follow Celectric's WhatsApp Channel →

Product details

The MTT MS3108 is a terminal block type frequency/analog converter with two independent, isolated outputs. It accepts dry contact, open collector, AC voltage pulse, DC voltage pulse, or 4~20mA DC pulse inputs, covering a frequency range within 0-20Hz to 0-20kHz, with a minimum pulse width of 20µs (40-60% duty ratio) and maximum continuous input of 30V DC or 40mA DC.

Output 1 and output 2 are independently configurable to current (0~20mA, 4~20mA) or voltage (10mV-20V range) – useful when one signal needs to feed a PLC and a second, separate signal needs to feed a recorder or indicator at the same time. Zero and span are each adjustable by about ±5% of span, with accuracy better than ±0.3% of span and temperature stability better than ±0.2% of span per 10°C change. Response time depends on input frequency: 8s at 20Hz, 1s at 200Hz, and 500ms at 2kHz and above.

There is 4-way isolation between input, output 1, output 2, and power, with dielectric strength of 2000V AC for 1 minute.

Power supply is flexible: 100-240V AC, 24V DC, or 110V DC, drawing 7.0VA (AC), 1.7W (24V DC), or 2.5W (110V DC). The unit mounts on DIN rail, measuring W49.8 × H102.0 × D40.0mm and weighing under 140g. It is rated for -5 to 55°C operation and -10 to 60°C storage.

Frequency RangeWithin 0-20Hz to 0-20kHz
Input TypesDry contact, open collector, AC voltage pulse, DC voltage pulse, 4-20mA DC pulse
Pulse Width / Duty Ratio20µs min.; 40-60%
Max Continuous Input30V DC max. / 40mA DC max.
Output 1 & 2Current (0-20mA, 4-20mA) or voltage (10mV-20V range), independently configurable
Zero / Span AdjustmentApprox. ±5% of span each
AccuracyBetter than ±0.3% of span
Response Time8s at 20Hz; 1s at 200Hz; 500ms at 2kHz and above
Temperature StabilityBetter than ±0.2% of span per 10°C change
Power Supply100-240V AC, 24V DC, or 110V DC
Power Consumption7.0VA (AC), 1.7W (24V DC), 2.5W (110V DC)
Isolation4-way isolation between input, output 1, output 2, and power
Dielectric Strength2000V AC for 1 minute
Enclosure / MountingDIN rail mounting
DimensionsW49.8 × H102.0 × D40.0 mm
Weight140g max.
Operating Temperature-5 to 55°C
Storage Temperature-10 to 60°C

Frequently Asked Questions

What is the MS3108 used for?
It converts a pulse train from a flow meter, tachometer, or similar sensor into two independent, isolated DC outputs, so one sensor reading can feed two separate systems — for example a control loop and a totalizer or recorder.

Can the MS3108 be used with AC power instead of 24V DC?
Yes. The MS3108 accepts 100-240V AC, 24V DC, or 110V DC, so it can be powered directly from panels that don’t have a dedicated 24V DC supply.

What’s the difference between the MS3108 and the MS3008?
The MS3108 gives two independent isolated outputs from one pulse input and can run on AC or DC power. The MS3008 is a single-output converter powered only by 24V or 12V DC. Choose the MS3108 when the same pulse signal needs to feed two separate devices, or when only AC mains power is available at the panel.

How do I know which MS3108 configuration I need?
It depends on your sensor’s pulse type and frequency range, the output ranges needed on Output 1 and Output 2, and your available power supply. We’re happy to confirm the right configuration before you order.

Download MTT MS3108 Terminal Block Type Frequency/Analog Converter information here

Datasheet: MTT_SpecSheet_MS3108_Rev200_E

Manual: MTT_Manual_MS3108_Rev150_E

Not sure this is the right instrument?

Tell us about your application and our engineers will recommend the right model.

Shopping Cart

Search 3,000+ products

Type a model number, brand or product type.

Popular categories
Can't find it? Tell us what you need. Request a Quote →