WhatsApp Us -- Email Us

Contrec 515 Heat Calculator (HC01)

SKU: 515–HC01

Heat Calculator for Pulse Flowmeter

Category: Heat Energy Calculators/BTU Meters

Price on request

Send us your requirement and we'll reply with a quotation and technical advice.

⏱ We reply within 1 working day. Specs & downloads ↓
🛠️
Lifetime technical support
🚚
Free domestic shipping
🎯
Calibration services

Follow Celectric's WhatsApp Channel →

Product details

The Contrec 515 HC01 Heat Calculator is designed to measure the volume, mass, and energy content of fluids in heating or cooling systems. It uses frequency volume flow input along with analog temperature inputs for supply and return.

This heat calculator supports various fluid types and modes, making it ideal for many heating and cooling applications. The 515-HC01 is compatible with a wide range of flowmeter frequency outputs, including mV signals, reed switches, Namur proximity switches, and pulse outputs, all easily configured through its user-friendly front-panel programming.

The 515-HC01 calculates mass flow and energy based on the Industrial Formulation (1997) (IAPWS) when the fluid is water. For other industrial fluids, it utilizes internal enthalpy and density tables to ensure accurate measurements.

With the Contrec 515-HC01, you can calculate mass flow and energy for various fluids, including Water, Glycol (35% Solution), Brine (27% CaC2), TYFOXIT F20, TYFOXIT F40, Essotherm 500/Thermaloil, THERMINOL 55, and even custom user-defined fluids.

Contrec-515-HC01-Application

FunctionHeat Calculator, Pulse/Frequency Flow (Volume); measures volume, mass, and energy content of fluids in heating/cooling systems using frequency volume flow input plus supply/return temperature; for water, calculates mass flow and energy per IAPWS Industrial Formulation (1997); for other fluids (Glycol 35% Solution, Brine 27% CaCl2, TYFOXIT F20/F40, Essotherm 500/Thermaloil, THERMINOL 55, or custom user-defined), uses internal enthalpy/density tables
DisplayBacklit LCD, 7-digit numeric (15.5mm) and 11-character alphanumeric (6mm) display, 0.3 second update rate
InputsFrequency input (millivolt signal, reed switch, Namur proximity switch, or pulse output, front-panel selectable); RTD PT100/PT500 (-200 to 350°C) supply and return temperature inputs; up to 4 analogue channels with 20-point non-linear correction
Accuracy0.05% full scale at 20°C; 0.1% typical across full temperature range; RTD 0.1°C typical
Outputs2 x isolated pulse (200mA/30Vdc) or 4-20mA outputs (0.05% accuracy); 2 standard relay outputs (3A max) for alarms, 2 additional optional
Power100-240Vac (50-60Hz) or 12-28V DC, up to 10W; front-panel adjustable 8-24V DC transducer supply
EnclosureIP65 (NEMA 4X) panel mount; conformal coating option extends temperature range
Operating Temperature+5 to +40°C standard; -20 to +60°C with conformal coating
Dimensions147 x 74 x 170mm (W x H x D); panel cut-out 139 x 67mm
CommunicationCOM-1 RS232, COM-2 RS485 or Ethernet (optional); ASCII, Modbus RTU/TCP-IP, and Printer protocols, 2400-19200 baud

Download Contrec 515 Heat Calculator (HC01) information here

Datasheet: 515-HC01-AP

Manual: 515-HC01-OM

Not sure this is the right instrument?

Tell us about your application and our engineers will recommend the right model.

Shopping Cart

Search 3,000+ products

Type a model number, brand or product type.

Popular categories
Can't find it? Tell us what you need. Request a Quote →