Contrec 515 Natural Gas Flow Computer (GN02)

The Contrec Model 515 (Application GN02) is the analogue input version of the 515 natural gas flow computer, built to take a standard analogue signal (4-20mA, 0-5V or 1-5V) from vortex, turbine, or other analogue-output gas flowmeters. It also supports stacked analogue flow inputs, so you can extend the turndown range on an installation with more than one meter run, and it applies non-linear correction to match the meter’s actual calibration curve rather than a straight-line approximation.

Gas compressibility and density are calculated using the AGA-8 Detailed Characterization Method across gas mixtures of up to 21 components, and gross heating value is worked out to ISO 6976 and GPA 2172-96. This is the same calculation basis used for fiscal and custody transfer gas metering, so it’s suitable for billing-grade applications, not just internal monitoring.

In actual application, this application code is normally paired with an analogue flowmeter that’s already installed and just needs a proper flow computer in front of it. The 515 has an onboard adjustable transducer excitation supply so you can power the field transmitter directly, plus 4-20mA retransmission and dual RS-232/RS-485 Modbus RTU ports so it talks to most SCADA or DCS systems without extra conversion gear. It also keeps a built-in log of totalizers, averages, and alarms, so you have an audit trail if anyone questions the readings later.

Before we quote this, we would normally check the flowmeter’s analogue output range, whether it’s a single or stacked input setup, the gas composition (for the AGA-8 calculation), and what output signals your control system needs. Hope this helps.

Contrec Model 515 GN02 Technical Specifications
● POWER SECTION
Power Supply Options115 Vac ±15% standard
230 Vac ±15% option (Model code selection E)
12 to 28 Vdc external field loop power input
Transducer Power OutputAdjustable 8 to 24 Vdc sensor excitation voltage regulated via software controls; maximum continuous current capacity up to 50mA.
Memory & Data SecurityNon-volatile flash memory permanently preserves accumulative gas totalizers, hardware calibration variables, and system configurations during full plant power blackout events.
● INPUT SECTION
Analog Flowmeter InputsSingle or dual stacked analog flow channels.
Configurable Signal Formats: 4 to 20 mA current loops, 0 to 5 Vdc, or 1 to 5 Vdc voltage signals.
Signal Correction: Multi-point non-linear correction filters can be assigned to reflect customized meter calibrations.
Compensation Analog InputsAnalog Temperature Input: RTD (Pt100) or linear 4 to 20 mA process loop.
Analog Pressure Input: 4 to 20 mA active linear transmitter input.
● OUTPUT SECTION
Analog Retransmission LoopFully isolated 4 to 20 mA DC current loop retransmission output channel with programmable range scaling.
Digital Pulse RetransmissionOpen collector transistor output featuring software-defined volumetric scaling factor and adjustable pulse width duration.
Serial InfrastructureRS-232 Port: Dedicated port optimized for direct PC terminal setup or local ticket receipt printing.
RS-485 Port (Optional): Multi-drop serial bus supporting robust long-distance plant networking.
Supported Protocols: Modbus RTU (Slave), standard Ticket Printer, and Contrec command-line protocols.
Local Display ScreenBacklit alphanumeric LCD display showcasing raw Volume, Volume Flowrate, Corrected Volume, Corrected Flowrate, Heat, Heat Flowrate, Mass, Mass Flowrate, Temperature, Pressure, and Compressibility Factor.
● PERFORMANCE
Calculation AccuracyBetter than ±0.01% of reading for all internal flow equations and mathematical AGA-8 density solutions.
Analog Transmittance PrecisionBetter than ±0.05% of full scale range under reference conditions.
Data Logging MatrixReal-Time Clock (RTC) event log memory block capturing over 1,000 entries for continuous process audit tracking.
● PHYSICAL
Mechanical Housing LayoutMolded field-mounting enclosure utilizing high-rigidity impact polymers (Optional flush panel mount, pipe track mount, or deployment within a heavy Ex410 explosion-proof housing).
Tactile Operator ArrayRobust elastomeric keyboard layout providing precise tactile user input feedback.
● STANDARDS CONFORMITY
Environmental SafeguardingStandard IP65 weatherproof frontal fascia shield protection.
*Note: Conformal PCB coating (Option C) is required for maximum environmental operating range and to avoid damage from moisture and corrosion.

Download Contrec 515 Natural Gas Flow Computer (GN02) information here

Datasheet: Contrec_515-GN02_Datasheet 
Manual: Contrec_515-GN02_Manual

Shopping Cart