Vogtlin Redy Smart (GSM) Digital Mass Flow Meter (with Modbus & Alarm)

Read more

Medium: Air/air
Measuring range: 2-100
Measuring unit: mln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 4-200
Measuring unit: mln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 10-500
Measuring unit: mln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 20-1000
Measuring unit: mln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 40-2000
Measuring unit: mln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 100-5000
Measuring unit: mln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 0.2-10
Measuring unit: ln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 0.4-20
Measuring unit: ln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 1-50
Measuring unit: ln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 2-100
Measuring unit: ln/min
Connection: G1/4" Inside thread

Available on backorder

Read more

Medium: Air/air
Measuring range: 2-100
Measuring unit: mln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 4-200
Measuring unit: ln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 9-450
Measuring unit: ln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 4-200
Measuring unit: mln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 9-450
Measuring unit: ln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 0.4-20
Measuring unit: ln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 2-100
Measuring unit: mln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 20-1000
Measuring unit: mln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 40-2000
Measuring unit: mln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 100-5000
Measuring unit: mln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 0.2-10
Measuring unit: ln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 1.0-50
Measuring unit: ln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 2-100
Measuring unit: ln/min

Available on backorder

Read more

Medium: Air/air
Measuring range: 4-200
Measuring unit: ln/min

Available on backorder

The red-y smart series by Vögtlin delivers high-precision, industrial-grade thermal mass flow meters and controllers designed for seamless measurement and regulation in gas delivery systems and plant engineering applications. Utilizing advanced MEMS CMOS semiconductor sensor technology embedded directly within the gas stream, these instruments offer exceptional accuracy, robust reliability, and complete immunity to pressure and temperature variations. The series features standard digital (Modbus RTU) and analog interfaces combined into a single, compact unit, ensuring ultimate versatility for automated factory networks. Available in and versions, the mass flow controllers integrate a tightly sealed, fast-acting control valve with response times of approximately 300 ms, significantly minimizing loop settling times and optimizing precise gas routing in harsh industrial environments.

Key Product Features

  • High-Accuracy Dual-Version Calibration: Offers standard accuracy of ±1.0% of full scale or a option reaching up to ±0.3% of full scale plus ±0.5% of reading.
  • Ultra-Wide Turndown & Dynamics: Provides a standard dynamic turndown ratio of 1 : 100, allowing precise mass flow monitoring from highly granular baselines up to full scale limits.
  • High-Speed, Leak-Tight Regulation: Integrated control valves feature a fast response time of approx. 300 ms and an exceptional helium leak rate of less than 1×10¹&sup0; mbar l/s He for tight shutoff.
  • 2-in-1 Combined Interfaces: Equipped with a digital Modbus RTU RS-485 network bus interface and standard analog outputs (4-20mA / 0-10V) working simultaneously.
  • Local Indication & Advanced Multi-Gas: Available with an optional built-in display or an onboard multi-color LED status indicator, supporting pre-calibrated multi-gas programming to switch fluid curves on the fly.
Technical Specifications
● POWER SECTION
Power Requirements24 VDC (+10% / -15%)
Power Consumption
Device TypeCurrent (Max)Power (Max)
Mass Flow Meter (GSM)50 mA1.2 Watt
Mass Flow Controller (GSC)250 mA6.0 Watt
● INPUT SECTION
Measurement PrincipleThermal mass flow measurement with premium CMOS semiconductor sensor technology.
Full Scale Flow RangesFrom 0…10 ln/min up to 0…450 ln/min depending on model size and gas configuration.
Gas CompatibilityPre-calibrated for standard industrial and process gases. Onboard multi-gas memory allows manual selection or setpoint control of alternate gas programming profiles via digital communication.
● OUTPUT SECTION
Analog Interface OutputSimultaneous, user-configurable standard analog signals:
Current: 4 to 20 mA or 0 to 20 mA DC
Voltage: 0 to 10 V, 2 to 10 V, 0 to 5 V, or 1 to 5 V DC
Digital Interface OutputModbus RTU protocol via RS-485 serial bus (standard).
Optional Industrial Ethernet configurations available upon request.
Status IndicationOnboard multi-color LED status indicator lamps or an optional integrated digital LCD window showcasing real-time flow rate, accumulative totalizer metrics, and configured units.
● PERFORMANCE
Measurement Accuracy<Standard> Version: ±1.0% of full scale value
<Hi-Performance> Version: ±0.3% of full scale + ±0.5% of actual reading
Dynamic Range (Turndown)1 : 50 standard turndown (extended turndown ratios 1:100 available on special factory request).
Repeatability±0.2% of full scale value.
Controller Response TimeApproximately 300 ms dynamic step settling loop time for GSC controller models.
Control Valve Leak RateTightly sealed mechanics featuring a low seat leak rate of less than 1×10¹&sup0; mbar l/s He.
Pressure & Temperature SensitivityPressure Dependent Coefficient: ±0.2% of reading per bar typical (Air).
Temperature Dependent Coefficient: ±0.025% of full scale per °C typical.
● STANDARDS CONFORMITY
Environmental LimitsAmbient Operating Range: 0 to +50°C
Maximum Process Pressure: Up to 11 bar g standard.
Engineering Design BaseSwiss-engineered technology manufactured in strict compliance with CE directives under certified ISO 9001 quality infrastructure systems.

Datasheet: Vogtlin-Red-y-Smart_Datasheet
Manual: Vogtlin_Red-y-Smart_Operating-Manual

Shopping Cart


Do you want to hide this popup?