E+E EE100Ex Intrinsically Safe Humidity and Temperature Sensor
Measuring humidity in explosion-hazard areas calls for certified equipment. The E+E EE100Ex is intrinsically safe and complies with ATEX (Europe) and IECEx (international) classifications for use in gas atmospheres up to Zone 1.
How It Works
A very robust sensing head, proprietary sensor protection and measurement electronics encapsulated in the probe give the EE100Ex its accuracy and long-term stability. Besides relative humidity and temperature, it calculates dew point and frost point, and outputs on two galvanically isolated 4–20 mA loops in 2-wire technology.
Key Features
- Intrinsically safe: ATEX and IECEx for gas up to Zone 1
- Measures RH and temperature; calculates dew point and frost point
- Two galvanically isolated 4–20 mA outputs, 2-wire
- Robust metal IP65 enclosure
- Wide choice of filter caps
- Encapsulated electronics for long-term stability
Applications
- Explosive and hazardous storage rooms
- Utility tunnels
- Pharmaceutical production in Ex areas
Industries Served
- Oil, gas and chemical
- Pharmaceutical
- Utilities
Frequently Asked Questions
Which hazardous-area approvals does the EE100Ex have?
ATEX (Europe) and IECEx (international) for gas atmospheres up to Zone 1.
What outputs does the EE100Ex provide?
Two galvanically isolated 4–20 mA outputs in 2-wire technology.
Need help choosing the right E+E EE100Ex configuration? Contact Celectric for a quotation, datasheet and technical support in Malaysia.