Contrec 515 Add/Subtract Flow Computer (FA03)

The Contrec Model 515 (Application FA03) is an add/subtract flow computer for energy measurement, built to take two independent flow inputs and either add them together or subtract one from the other to give a combined or net result. It’s the energy-metering version of the standard 515 add/subtract application, so it’s normally used on thermal energy loops where you need a running total across two flow paths, not just a single meter reading.

The two input channels accept a wide range of frequency signals (millivolt, reed switch, Namur proximity, open collector) or scaled analogue signals, so it can take a re-transmitted signal from another field flow computer on one channel and a raw pulse or millivolt signal from a flowmeter on the other, if that’s how your setup is wired.

In actual application, this application code is normally paired with two flow measurement points feeding into one energy total – for example a supply and return, or two parallel lines. The 515 has an onboard adjustable transducer excitation supply so you can power the field sensors directly, plus freely assignable high and low alarms, 4-20mA retransmission, and dual RS-232/RS-485 Modbus RTU ports so it reports into your existing SCADA or DCS setup.

Before we quote this, we would normally check the signal type on each channel (frequency or analogue), whether you need addition or subtraction between the two, and what alarm and output signals your control system needs. Hope this helps.

  • Data Logging Matrix: Real-Time Clock (RTC) event log memory block capturing over 1,000 entries for thorough audit tracking.
Contrec Model 515 FA03 Technical Specifications
● POWER SECTION
Power Supply Inputs115 Vac ±15% standard (Optional: 230 Vac ±15% configuration)
12 to 28 Vdc external line loop power
Transducer Power OutputAdjustable 8 to 24 Vdc excitation output voltage regulated via software controls; maximum continuous current capacity up to 50mA.
Memory & Data SecurityNon-volatile flash memory permanently preserves accumulative totals, hardware constants, and system configurations during full power blackouts.
● INPUT SECTION
Frequency Pulse InputsTwo independent input channels supporting a 0Hz to 10kHz frequency range.
Compatible Inputs: Millivolt signals, reed switches, Namur proximity sensors, and logic pulse trains.
Analog Loop InputsTwo independent 4 to 20 mA active current loops.
Signal Filtering: Configurable non-linear correction curves, linear scaling, and low-flow cutoff points.
Main Menu VariablesDefault tracking parameters: Total 1 (MWh), Flowrate 1 (MW), Total 2 (MWh), Flowrate 2 (MW), Resulting Total (MWh), and Resulting Flowrate (MW).
● OUTPUT SECTION
Analog Loop RetransmissionFully isolated 4 to 20 mA DC current loop retransmission output channel with programmable scaling.
Digital Pulse RetransmissionOpen collector transistor output featuring software-defined volumetric scaling factor and adjustable pulse width duration.
Serial InfrastructureRS-232 Port: Dedicated link optimized for direct PC terminal calibration or local ticket receipt printing.
RS-485 Port (Optional): Multi-drop serial bus supporting robust long-distance plant networking.
Supported Protocols: Modbus RTU, Ticket Printer, and Contrec command-line protocols.
Fascia Operator InterfaceBacklit alphanumeric LCD screen showing real-time concurrent totals, differential energy results, user-programmed tags, and secondary language options.
● PERFORMANCE
Calculation AccuracyBetter than ±0.01% of reading for all internal mathematical energy equations.
Analog Transmittance PrecisionBetter than ±0.05% of full scale range under reference conditions.
● PHYSICAL
Mechanical Housing LayoutMolded field-mounting enclosure utilizing high-rigidity impact polymers (Optional flush panel mount, pipe track mount, or deployment within a heavy Ex410 explosion-proof housing).
Tactile Operator ArrayRobust, weather-sealed elastomeric keyboard layout providing precise tactile user input feedback.
● STANDARDS CONFORMITY
Environmental SafeguardingStandard IP65 weatherproof frontal fascia protection.
*Note: Conformal PCB coating (Option C) is available to protect internal circuits from harsh humidity and ambient chemical corrosion.

Download Contrec 515 Add/Subtract Flow Computer (FA03) information here

Datasheet: Contrec_515-FA03_Datasheet 
Manual: Contrec_515-FA03_Manual