Contrec 214Di.2

The Contrec 214Di.2 is the standard wall mount version of the 214Di ATEX/IECEx intrinsically safe Batch Controller, fitted with standard cable gland holes. This is the version we quote most often, since it goes straight onto a wall or bracket near the flowmeter and valve skid without needing a panel cut-out.

Like the rest of the 214Di family, it takes a pulse or frequency signal from any digital output flowmeter and drives two solid state relay outputs, so it can run a two-stage valve sequence for accurate batching, coarse flow first and a slow trickle to close in on the target. It carries ATEX and IECEx certification for hazardous area use, and the magnetic key lets the technician reconfigure the K-factor and settings from outside the enclosure without opening it live.

Before we quote this, we would normally check the zone classification of the installation area, the flowmeter’s own hazardous area certificate, and confirm the customer’s cable entry sizes so the right gland is fitted. Power is 9-28V DC with battery backup for the display and logic only, so we would also confirm the DC supply is available at the mounting location. Hope this helps.

FunctionIntrinsically safe (ATEX/IECEx) Batch Controller for digital output flowmeters, controlling batch quantities via solid state relay outputs
MountingWall mounting (standard cable gland holes)
Input SignalPulse or frequency: sine wave (15mV P-P min), open collector, reed switch, or pulse; 0Hz to 10kHz
K-Factor RangeProgrammable from 0.0001 to 999,999 pulses per unit
Intrinsic Safety ParametersUi = 24V, Ii = 20mA, Pi = 320mW; Cext = 60µF, Lext = 1.5H
Display7-digit 10mm LCD (Batch Total), 5-digit 8.5mm LCD (Preset), Accumulated Total via dedicated key; fully programmable decimal points
Outputs2 x solid state relay outputs, 200mA/30Vdc max, for single or two-stage valve control with 0-9 second programmable delays
Hazardous Area RatingATEX II 2G Ex ia IIB T4 Gb (BVS 15 ATEX E 106 X); IECEx Ex ia IIB T4 Gb (IECEx BVS 15.0099X); CSA Class 1, Group C & D (104840-5)
Power Options9-28V DC (4mA max); 2 x lithium battery packs for display/logic backup (does not power solenoids or sensors)
EnclosureIP67 (NEMA 4X) watertight, polycarbonate and ABS construction
Operating Temperature-20 to +60°C
Dimensions151 x 98 x 26mm (H x W x D)
OperationSimple 3-key keyboard; magnetic access strip allows hazardous-area reconfiguration without opening the enclosure; CE compliant

Download Contrec 214Di.2 information here

Datasheet: Contrec_214D_Batch_Controller

Manual: 214D-M-V7.1_ATEX

Shopping Cart