Contrec 515 Open Channel Flow Computer (OC01)

The Contrec 515 OC01 open channel flow computer is designed to accurately measure fluid flow in open channels. It utilizes a frequency flow meter that provides a velocity proportional output, along with an analogue level input. By combining the level input with specific dimensional parameters, the system calculates the cross-sectional area of the fluid flowing through the channel.

This flow measurement system supports various standard channel shapes, including Rectangular, Triangular, Trapezoidal, Circular, and Half-Round. Additionally, for unique channel shapes, the Non-linear selection feature allows the level input to accurately represent the actual cross-sectional area of the fluid at different levels, making it a versatile solution for industrial flow measurement applications.

FunctionOpen Channel Flow Computer, measures fluid flow in open channels (flumes/weirs) using a frequency flowmeter (velocity proportional output) combined with an analogue level input; calculates cross-sectional area of flow for standard channel shapes (Rectangular, Triangular, Trapezoidal, Circular, Half-Round) or unique shapes via a Non-linear selection feature
DisplayBacklit LCD, 7-digit numeric (15.5mm) and 11-character alphanumeric (6mm) display, 0.3 second update rate
InputsFrequency input (pulse, turbine coil, or Namur proximity switch up to 10kHz) for velocity; 4-20mA/0-5V/1-5V analogue level input; up to 4 analogue channels with 20-point non-linear correction
Accuracy0.05% full scale at 20°C; 0.1% typical across full temperature range
Outputs2 x isolated pulse (200mA/30Vdc) or 4-20mA outputs (0.05% accuracy); 2 standard relay outputs (3A max) for alarms, 2 additional optional
Power100-240Vac (50-60Hz) or 12-28V DC, up to 10W; front-panel adjustable 8-24V DC transducer supply
EnclosureIP65 (NEMA 4X) panel mount; conformal coating option extends temperature range
Operating Temperature+5 to +40°C standard; -20 to +60°C with conformal coating
Dimensions147 x 74 x 170mm (W x H x D); panel cut-out 139 x 67mm
CommunicationCOM-1 RS232, COM-2 RS485 or Ethernet (optional); ASCII, Modbus RTU/TCP-IP, and Printer protocols, 2400-19200 baud