Adtek CS2-TM Analogue Flow Totalizer

SKU: CS2-TM Analogue

ADtek CS2-TM (Analogue Input) - a 10-digit totalizer and rate/batch controller for 0~10V/4~20mA flowmeter signals (with square root function) or mV shunt signals for Amp-Hour, with up to 4 programmable relays.

Category: Batch Controllers, Digital Indicators, Flow Indicators, Flow Totalizers

Price on request

Send us your requirement and we'll reply with a quotation and technical advice.

⏱ We reply within 1 working day. Specs & downloads ↓
🛠️
Lifetime technical support
🚚
Free domestic shipping
🎯
Calibration services

Follow Celectric's WhatsApp Channel →

Product details

We had an enquiry from a customer measuring flow through an analogue output flowmeter (0~10V or 4~20mA), who needed both a running total and a batch cut-off relay – not just an instant rate reading. The ADtek CS2-TM (Analogue Input) is built for exactly this: totalizing, rate display, and batch control from one analogue signal.

This looks simple, but the CS2-TM-Analogue reads two quite different kinds of input under one model: a standard 0~10V or 0(4)~20mA signal from a flowmeter (with a built-in square root function, since flow signals from differential-pressure type meters are often non-linear), or a low-level 0~50/60/100mV signal straight off a current shunt, used for Amp-Hour totalizing rather than flow. Getting the right input type and range set is what makes the totalized reading actually correct.

In actual application, it gives you a dual live display – a 10-digit totalizer or batch counter alongside a 4 2/3 digit immediate value (or 6-digit batch). There are 4 pre-set banks for relay functions, each with its own scaling, selectable via the 3 external control inputs or the front key. Up to 4 relays can each be assigned independently to the immediate value or to totalizer/batch/batch-counter functions, with N/R/C batch control modes, hysteresis, and energize/de-energize delay settings. Analogue output, pulse output, and RS-485 (Modbus RTU, up to 38400bps) are available as options. CE and RoHS compliant.

From our experience, before we quote this, we would normally check whether you’re measuring a flowmeter’s analogue output or a shunt’s mV signal for Amp-Hour, the exact input range, and how many relays and what functions you need them for. Hope this helps.

Series: ADtek CS2-TM-Analogue (10-digit rate/batch counter, analogue input)
Input: DC 0~10V or 0(4)~20mA from flowmeter (with square root function), or 0~50/60/100mV from current shunt for Amp-Hour control
Display: Dual screen – 10-digit Totalizer/Batch counter + 4 2/3 digit Immediate Value (PV), or 6-digit Batch, programmable
Relay banks: 4 pre-set banks, each with its own scaling, selectable via 3 External Control Inputs or front key
Relays: Up to 4, individually programmable to PV or Totalizer/Batch/Batch Counter, with Hi/Lo/Hold energize modes, hysteresis, energize/de-energize delay, and RS-485-command latch
Control inputs: 3 external DI, individually programmable (PV hold/reset/max-min hold, or Totalizer/Batch reset/gate)
Optional outputs: Analogue output, Pulse output, RS-485 (Modbus RTU, up to 38400bps)
Approvals: CE, RoHS

Download ADtek CS2-TM Analogue Flow Totalizer information here

Datasheet: C2-13-CS2-TM-Analogue-DataSheet-EN-080101-101224.pdf
Manual: C2-13-CS2-TM-Analogue-Manual-EN-070901.pdf