Gems Sensors 25365

Flow Setting: 0.50 – 20GPM
Body Material: Brass
Port Size: 1/2″ NPT Female
Switch Type: SPDT (20VA)

Gems FS-10798 Series Externally Adjustable Flow Switch Technical Specifications
● GENERAL
DescriptionExternally adjustable piston-type flow switch for water, oils and gases. Ideal for protecting machine tools from coolant flow failure, protecting bearings from loss of lubricant, or assuring proper air flow. Offers an infinite number of flow settings at pressures up to 1000 PSIG, with low pressure drop and precise repeatability. The adjusting vane is field-adjustable with an ordinary flat-bladed screwdriver and is set-screw-locked for tamper-free operation after calibration.
Operating PrincipleAn externally rotatable vane sits in the main flow path. The magnet-carrier piston is located in a bypass flow chamber. Pressure differential caused by flow around the adjusting vane displaces the spring-biased piston, which actuates a hermetically sealed SPDT reed switch within the unit.
Flow Rate SettingsLiquids: infinite adjustment between 0.5 GPM and 20.0 GPM. Air/Gases: see Air/Gas Flow Adjustment Ranges below.
Port Size1/2-14 NPT.
Primary Construction MaterialBrass or Stainless Steel.
Setting TypeAdjustable.

 

● WETTED MATERIALS
HousingBrass or 316 Stainless Steel.
Piston — In Brass HousingPolysulfone for water; brass for oil or air.
Piston — In Stainless Steel Housing316 Stainless Steel only.
Spring316 Stainless Steel.
O-RingViton®.
Other Wetted PartsEpoxy.

 

● PERFORMANCE / RATINGS
Pressure Rating — Operating1000 PSIG (69 bar).
Pressure Rating — Proof2500 PSIG (172 bar).
Pressure Rating — Burst5000 PSIG (345 bar).
Operating Temperature — Brass or S.S. Piston-20°F to +300°F (-29°C to +148.9°C).
Operating Temperature — Polysulfone Piston-20°F to +225°F (-29°C to +107.2°C).
Repeatability1% maximum deviation.
Set Point Accuracy±10% maximum.
Set Point Differential15% maximum.

 

● ELECTRICAL
SwitchSPDT, 20 VA.
Inlet/Outlet Ports1/2-14 NPT.
Electrical TerminationNo. 18 AWG, 24″ L., polymeric lead wires.

 

● DIMENSIONS
With Wire Leads and Strain Relief3/4″ (19.0 mm); 2″ (50.8 mm); 5/8″ (15.8 mm); 4-1/8″ (104.7 mm); 1-1/4″ (31.7 mm). 1/2″ NPT both ports.
With 1/2-14 NPT Conduit Connector1/2″ (12.7 mm); 1-1/16″ (26.9 mm) max. in.

 

● AIR/GAS FLOW ADJUSTMENT RANGES
ApplicabilityWater or oil flow units should not be utilized for air/gas applications. The FS-10798 Gas Flow configuration uses a special dash-pot piston for reliability. Ranges shown are typical for air service; for other gases, the flow range will vary with gas density — consult factory.
For 5 PSIG Line*1 to 75 SCFM approx.
For 100 PSIG Line3 to 160 SCFM approx. *Minimum 5 PSI line pressure required.

 

● STANDARDS & APPROVALS
UL Recognition (General)U.L. Recognized — File No. E31926.
UL Approval (Hazardous Locations)FS-10798 switches are U.L. Approved for Class I, Division 2, Groups A, B, C, D hazardous locations. U.L. Approved — File No. E183854.

 

● STANDARD WIRING COLOR CODE
Wire ColorTerminal
OrangeN.O.
BlackCommon
RedN.C.

 

● ORDERING INFORMATION — STANDARD MODELS
MediaHousingPistonPart No. — With Lead WiresPart No. — With 1/2″ Conduit Connector
LiquidsBrassBrass (for Oils)6120549073 ⚡
Polysulfone (for Water)25357 ⚡25363 ⚡
316 Stainless Steel316 Stainless Steel2535825364 ⚡
GasesBrassBrass25359 ⚡25365 ⚡
316 Stainless Steel316 Stainless Steel2536025366
⚡ = Stock item. Specify part number based on desired media, piston material and electrical termination. Notes: (1) Temperature changes will slightly affect the standard water or gas flow settings listed; oil flow settings will vary with temperature and viscosity. (2) Use of 50 micron filtration is recommended.

 

● PRESSURE DROP — TYPICAL (REFERENCE CURVES)
0.5 GPM Unit (Part No. 25357)Pressure drop rises from near 0 PSID at 0 GPM to approx. 2.2 PSID at 2.0 GPM (non-linear curve with an inflection near 1.0–1.2 GPM).
10 GPM and 20 GPM Units (Part No. 25358)Pressure drop rises from near 0 PSID at 0 GPM to approx. 10–14.5 PSID at 25–30 GPM, following an increasing (roughly quadratic) curve. Tests conducted with units in horizontal position with water at +70°F (21°C); results vary slightly for vertically mounted units.

Download Gems Sensors 25365 information here