Contrec 515 Ideal Gas Flow Computer (GC06)

Gas plants using differential pressure flowmeters, vapour or non-liquefied gas lines, need flow numbers corrected for real gas behaviour, not just a simple DP-to-flow conversion. The Contrec 515 GC06 Ideal Gas Flow Computer is built for this, working with single or stacked DP volumetric transmitters.

It runs the standard DP flow equations while accounting for the primary element’s own reference calibration conditions, and resolves gas density and compressibility in real time using standard equations of state, so the actual gas quantity is worked out correctly rather than assumed. Stacked DP inputs extend the measurable flow range while keeping low-flow accuracy intact, which matters on lines with wide turndown.

In actual application, this unit usually sits out on process plant rather than in a control room, so it comes in a weatherproof IP65 housing with a backlit alphanumeric LCD and a keypad built for field use. It also has an adjustable 8-24V DC sensor supply, isolated 4-20mA loop retransmission, and dual RS-232/RS-485 Modbus RTU ports for integration into plant automation networks.

Before we quote this, we would normally check your DP transmitter range (single or stacked), your gas composition, and your line pressure and temperature.

Hope this helps.

Contrec Model 515 GC06 Technical Specifications
● POWER SECTION
Power Supply Options115 Vac ±15% standard (Optional: 230 Vac ±15% layout via model code E)
12 to 28 Vdc external field loop power input
Transducer Power OutputAdjustable 8 to 24 Vdc sensor excitation voltage regulated via software controls; maximum continuous current capacity up to 50mA.
Data Security RetentivityNon-volatile flash memory ensures that all gas totalizers, user variables, and system logs remain permanently stored during full plant power failure events.
● INPUT SECTION
Differential Pressure InputsSingle or dual stacked analog differential pressure input channels.
Configurable Signal Formats: 4 to 20 mA current loops, 0 to 5 Vdc, or 1 to 5 Vdc voltage signals.
Signal Customization: Programmable linear scaling, noise filtering, and custom low-flow cutoff boundaries.
Compensation Analog InputsAnalog Temperature Input: RTD (Pt100) or linear 4 to 20 mA process loop.
Analog Pressure Input: 4 to 20 mA active linear transmitter input.
● OUTPUT SECTION
Analog Retransmission LoopFully isolated 4 to 20 mA DC current loop retransmission output channel with programmable range scaling.
Digital Pulse RetransmissionOpen collector transistor output featuring software-defined volumetric scaling factor and adjustable pulse width duration.
Serial InfrastructureRS-232 Port: Dedicated port optimized for direct PC terminal setup or local ticket receipt printing.
RS-485 Port (Optional): Multi-drop serial bus supporting robust long-distance plant networking.
Supported Protocols: Modbus RTU (Slave), standard Ticket Printer, and Contrec command-line protocols.
Local Display ScreenBacklit alphanumeric LCD display showcasing Volume, Volume Flowrate, Corrected Volume, Corrected Flowrate, Mass, Mass Flowrate, Temperature, Pressure, and Compressibility Factor.
● PERFORMANCE
Calculation AccuracyBetter than ±0.01% of reading for all internal flow metrics, mass conversion equations, and general gas density math.
Analog Transmittance PrecisionBetter than ±0.05% of full scale range under reference conditions.
Data Logging MatrixReal-Time Clock (RTC) event log memory block capturing over 1,000 entries for continuous process audit tracking.
● PHYSICAL
Mechanical Housing LayoutMolded field-mounting enclosure utilizing high-rigidity impact polymers (Optional flush panel mount, pipe track mount, or deployment within a heavy Ex410 explosion-proof housing).
Tactile Operator ArrayRobust elastomeric keyboard layout providing precise tactile user input feedback.
● STANDARDS CONFORMITY
Environmental SafeguardingStandard IP65 weatherproof frontal fascia shield protection.
*Note: Conformal PCB coating (Option C) is highly recommended to prevent internal circuitry degradation from severe moisture and ambient corrosion.

Download Contrec 515 Ideal Gas Flow Computer (GC06) information here

Datasheet: Contrec_515-GC06_Datasheet 