WhatsApp Us -- Email Us

Contrec 515 Dual Stage Batch & Flow Controller (BF01)

Contrec 515 Gas Density Converter (DG01)

SKU: 515–DG01

Gas Density Converter

Category: Density Converter

Price on request

Send us your requirement and we'll reply with a quotation and technical advice.

⏱ We reply within 1 working day. Specs & downloads ↓
🛠️
Lifetime technical support
🚚
Free domestic shipping
🎯
Calibration services

Follow Celectric's WhatsApp Channel →

Product details

The Contrec 515 DG01 Gas Density Converter works with Sarasota-type density meters, such as the Industrial Density Meter FD910, along with temperature and pressure transmitters, and an optional Customer Defined Function input for a custom look-up table.

It calculates line density straight from the density meter’s output, using the precise average pulse period from the meter, and corrects this with temperature and pressure to reference standard conditions. From this it also works out specific gravity and other density-related figures.

It accepts most density meter pulse output types, millivolt signal, reed switch, Namur proximity switch, or pulse train, selectable from the front panel. For gas properties, it lets you pick the equation of state that fits your gas, Ideal Gas, Redlich-Kwong, Soave-Redlich-Kwong, or Peng-Robinson, for accurate results on the vapour phase.

Before we quote this, we would normally check your density meter model and pulse output type, your gas composition, and your line pressure and temperature.

Hope this helps.

FunctionGas Density Converter; works with Sarasota-type density meters (e.g. FD910), temperature and pressure transmitters, and an optional Customer Defined Function (look-up table) input; calculates line density from the density meter output plus temperature/pressure to reference standard conditions, along with specific gravity; supports selectable equations of state (Ideal Gas, Redlich-Kwong, Soave-Redlich-Kwong, Peng-Robinson) for the vapour phase
DisplayBacklit LCD, 7-digit numeric (15.5mm) and 11-character alphanumeric (6mm) display, 0.3 second update rate
InputsDensity meter pulse input (millivolt signal, reed switch, Namur proximity switch, or pulse train, front-panel selectable); RTD PT100/PT500 (-200 to 350°C) temperature and 4-20mA pressure inputs; up to 4 analogue channels with 20-point non-linear correction
Accuracy0.05% full scale at 20°C; 0.1% typical across full temperature range; RTD 0.1°C typical
Outputs2 x isolated pulse (200mA/30Vdc) or 4-20mA outputs (0.05% accuracy); 2 standard relay outputs (3A max) for alarms, 2 additional optional
Power100-240Vac (50-60Hz) or 12-28V DC, up to 10W; front-panel adjustable 8-24V DC transducer supply
EnclosureIP65 (NEMA 4X) panel mount; conformal coating option extends temperature range
Operating Temperature+5 to +40°C standard; -20 to +60°C with conformal coating
Dimensions147 x 74 x 170mm (W x H x D); panel cut-out 139 x 67mm
CommunicationCOM-1 RS232, COM-2 RS485 or Ethernet (optional); ASCII, Modbus RTU/TCP-IP, and Printer protocols, 2400-19200 baud

Download Contrec 515 Gas Density Converter (DG01) information here

Datasheet: 515-DG01-AP

Manual: 515-DG01-OM

Not sure this is the right instrument?

Tell us about your application and our engineers will recommend the right model.

Shopping Cart

Search 3,000+ products

Type a model number, brand or product type.

Popular categories
Can't find it? Tell us what you need. Request a Quote →