Precision Digital PD765 Trident: Universal Process & Temp Meter

The PD765 Trident is one of the most versatile panel meters on the market. It accepts Process (4-20mA, 0-10V) and Temperature (TC/RTD) inputs without any jumper changes. Features a sunlight-readable display and NEMA 4X front.

The Precision Digital Trident PD765 digital panel meter is a highly adaptable device, perfect for various process and temperature applications. It features a compact 1/8 DIN enclosure with a durable NEMA 4X front, making it suitable for tough environments.

This meter can be easily programmed in the field to accept different inputs, including:

  • Process voltage (0-5 V, 1-5 V, etc.)
  • Current (4-20 mA)
  • 100 Ohm RTDs
  • The four most common thermocouples

The standard Trident meter features a display height of 0.56″ (14.2 mm), while the Trident X2 boasts a larger display at 1.2″ (30.5 mm). You can adjust the display intensity to ensure visibility in various lighting conditions, even in direct sunlight.

Setting up the meter is straightforward, thanks to the four front panel pushbuttons, the free MeterView software, or the convenient copy function. The PD765 also offers several options to enhance its functionality, including:

  • Two relays
  • A 4-20 mA output
  • A 24 V transmitter power supply
  • Modbus® serial communications

With its versatility and user-friendly features, the Precision Digital Trident PD765 is an excellent choice for anyone needing a reliable digital panel meter for their process and temperature monitoring needs.

  • 4-20 mA, ± 10 V, TC & RTD Inputs
  • NEMA 4X, IP65 Front
  • Shallow Depth Case 3.6″ Behind Panel
  • Operating temperature range of between -40°C and 65°C
  • Universal Power Supply 85-265 VAC
  • Two Relays Option with Alternation & Time Delays
  • 4-20 mA Analog Output Option
  • 24 VDC @ 200 mA Transmitter Power Option
  • RS-232, RS-485 Serial Communication Options
  • Free Modbus® RTU Protocol & LabVIEW™ Driver
  • Sunlight Readable Display
  • 3 Year Warranty
  • Free MeterView Software Download

General Specifications

Display
Trident: 0.56” (14.2 mm) red LED
Trident X2: 1.20” (30.5 mm) red LED
4 digits (-1999 to 9999)
Display Intensity
Eight user selectable intensity levels
Front Panel
NEMA 4X, IP65; panel gasket provided
Programming Methods
Four front panel buttons, cloning with Copy feature, PC with MeterView or LabVIEW software, and Modbus registers. Certified LabVIEW driver available.
Noise Filter
Programmable 2 to 199 (0 will disable filter)
Display Update Rate
Process/RTD: 3.7-5/sec; TC: 1.8-2.5/sec
Overrange / Underrange
Display flashes 9999 / Display flashes -1999
Recalibration
All inputs are calibrated at the factory; recalibration is recommended at least every 12 months.
Max/Min Display
Stored until reset by user or meter is turned off.
Non-Volatile Memory
Settings stored for a minimum of 10 years.
Power Options
85-265 VAC, 50/60 Hz
90-265 VDC, 20 W max
12-36 VDC / 12-24 VAC, 6 W max
Required Fuse
UL Recognized, 5 A max, slow-blow; up to 6 meters may share one fuse.
Isolation
4 kV input/output-to-power line; 500 V input-to-output or output-to-24 VDC supplies.
(-6R5 & -6X5 skus only: 100 V output-to-24 VDC supply)
Operating / Storage Temp
-40 to 65°C / -40 to 85°C
Connections
Power & Signal: Removable screw terminal blocks accept 12 to 22 AWG.
Serial: RJ11 header, standard on all meters.
Enclosure
1/8 DIN, high impact plastic, 94V-0, color: gray
Weight
9.5 oz (269 g) (including options)
UL File Number
E160849; 508 Industrial Control Equipment
Warranty
3 years parts & labor

Process Inputs

Inputs
Field selectable: 0-20 mA, 4-20 mA, 1-5 V, ±10 V
Accuracy
±0.05% FS ±1 count; square root: ±0.1% FS ±2 counts
Low-Flow Cutoff
0 to 9999 (0 disables cutoff function)
Decimal Point
Up to 3 decimals: d.ddd, dd.dd, ddd.d, or dddd
Calibration
Scale without signal or calibrate with signal source (User programmable range)
Input Impedance
Voltage range: > 1 MΩ
Current Range: 50-100 Ω (varies with resettable fuse)
Transmitter Supply
Isolated, one or two transmitter supplies
P1: 24 VDC ±10% @ 200 mA max (-1 option)
P1 & P2: 24 VDC ±10% @ 200 mA & 40 mA max (-2 option)

Process Input Temperature Drift

ConditionCurrent AccuracyVoltage Accuracy
0 to 65°C ambient±0.20% FS (50 PPM/°C)±0.02% FS (1.7 PPM/°C)
-40 to 0°C ambient±0.80% FS±0.06% FS

Temperature Inputs

Inputs
Factory calibrated, field selectable: Type J, K, T, or E thermocouples and 100 Ω platinum RTD (0.00385 or 0.00392 curve)
Resolution
1°; Type T: 1° or 0.1°
Cold Junction Reference
Automatic
Offset Adjustment
Programmable to ±19.9°
Input TypeRangeAccuracy (0-65° C)Accuracy (-40-0° C)
Type J-58° to 1382° F
-50° to 750° C
±2° F / ±1° C±5° F / ±3° C
Type K-58° to 2300° F
-50° to 1260° C
±2° F / ±1° C±4° F / ±2° C
Type T-292° to 700° F
-180° to 371° C
±2° F / ±1° C±13° F / ±7° C
Type T (0.1° Res)-199.9° to 700.0° F
-180.0° to 371.0° C
±1.8° F / ±1° C±13° F / ±7.2° C
Type E-58° to 1578° F
-50° to 870° C
±2° F / ±1° C±11° F / ±6° C
100 Ω RTD-328° to 1382° F
-200° to 750° C
±1°F / ±1° C±5°F / ±3° C

Relays

Rating
2 Form C (SPDT); rated 3 A @ 30 VDC or 3 A @ 250 VAC resistive load; 1/14 HP @ 125/250 VAC inductive loads
Deadband
0-100% FS, user selectable
Relay Operation
  1. Automatic (non-latching)
  2. Latching
  3. Pump alternation control
Relay Reset
User selectable via front panel buttons or PC:

  1. Automatic reset only (non-latching)
  2. Automatic plus manual reset (non-latching)
  3. Manual reset only (latching)
  4. Manual reset only after alarm clears (latching)
Time Delay
0 to 199 seconds, on and off delays; programmable
Fail-Safe Operation
Programmable. Relay coils are energized in non-alarm condition. In case of power failure, relays will go to alarm state.

Isolated 4-20 mA Transmitter Output

Scaling Range
1.00 to 23.00 mA; reverse scaling allowed
Calibration
Factory calibrated 4.00 to 20.00 mA
Accuracy
±0.1% FS ±0.004 mA (Temp Drift: 50 PPM/°C)
Isolation
500 V input-to-output or output-to-24 VDC supplies; 4 kV output-to-power line

Output Loop Resistance

Power SupplyMinimumMaximum
24 VDC10 Ω700 Ω
35 VDC (external)100 Ω1200 Ω

Serial Communications

Compatibility
EIA-232, EIA-422, and EIA-485 with PDA7232 and PDA7422 Trident adapters.
Protocol
Selectable: PDC protocol (for MeterView) and Modbus RTU
Meter Address
PDC protocol: 0 to 99
Modbus protocol: 1 to 247
Baud Rate
300 to 19,200 bps
Parity (Modbus)
None (2 stop bits), even, or odd
Byte-to-Byte Timeout
0.01 to 2.54 seconds (Modbus only)
Note
Both downloadable protocol register tables can be found in the documentation list below.

Application

Pump Alternation

PD765 Pump Alternation Step 1 PD765 Pump Alternation Step 2

Mounting Dimensions

DC Voltage Digital Panel Meter Mounting Dimensions

Notes:

  1. Panel cutout required: 1.772″ x 3.622″ (45 x 92 mm)
  2. Panel thickness: 0.040″ – 0.250″ (1.0 – 6.4 mm)
  3. Mounting brackets lock in place for easy mounting

MeterView® for Trident

MeterView software allows remote programming and data acquisition of the Trident series. The remote programming allows for all available meter settings to be programmed from a personal computer through an easy user-friendly interface. The data acquisition allows the user to gather readings from up to 100 meters at user-selected intervals and generate charts using common tools like Microsoft® Excel.

Digital Panel Meters make a great front end to a PC-based data acquisition system. They are easy to set up, can be used for a wide range of inputs, will power the transmitter, and best of all provide a local display of the process. Precision Digital has the perfect package with its Trident Digital Panel Meters, a wide selection of serial adapters and converters and free MeterView software. Data is displayed on the PC and written to a file that could then be imported into a spreadsheet or other application.

Data Logging up to 100 Trident Meters

MeterView Software Interface Screenshot

Sample File Generated by MeterView®

Sample Excel Log File from MeterView

Great for tank level monitoring!

Ordering Example: System consisting of 10 Tridents & MeterView

QtyModelDescription
10PD765-6R2-10Trident with 2 Relays & 24 VDC Transmitter Supply
10PDA7422Trident RS-485 Serial Adapter
1PDA8485-IUSB to RS-422/485 Isolated Converter
1PDA7503-2MeterView Software for 1-10 Meters

Data Sheet: Predig PD765 Datasheets
Instruction Manual: Predig PD765 Manual

Shopping Cart