E+H Proline Promass G 100 Coriolis flowmeter

Promass G provides safe and accurate measurement of liquids and gases in high pressure applications up to 350 bar (5080 psi). Rupture disc and threaded process connections provide easy and safe integration. Combined with the smallest transmitter housing available today it delivers full performance on the smallest footprint. Designed for applications where space is a premium, Promass G 100 will be the preferred choice for system integrators, skid builders and equipment manufacturers.

● Easy and safe process integration – threaded connections
● Fewer process measuring points – multivariable measurement (flow, density, temperature)
● Space-saving installation – no in/outlet run needs
● Space-saving transmitter – full functionality on the smallest footprint
● Time-saving local operation without additional software and hardware – integrated web server
● Integrated verification – Heartbeat Technology

 

● Measuring principle operates independently of physical fluid properties such as viscosity or density
● Accurate measurement of liquids and gases in high-pressure applications.
Device properties
● Internal threads as process connection
● Process pressure up to 350 bar (5080 psi)
● Rupture disc available
● Robust, ultra-compact transmitter housing
● Pre‐configured plug connector
● Local display available

 

 

  • Measuring principle

    Coriolis

  • Product headline

    The most compact high‐pressure sensor with an ultra‐compact 
    transmitter. Accurate measurement of liquids and gases in high-pressure 
    applications.

  • Sensor features

    Easy and safe process integration – threaded connections. Fewer process 
    measuring points – multivariable measurement (flow, density, 
    temperature). Space‐saving installation – no in/outlet run needs. Internal 
    threads as process connection. Process pressure up to 350 bar (5080 
    psi).

  • Transmitter features

    Space‐saving transmitter – full functionality on the smallest footprint.
    Time‐saving local operation without additional software and hardware –
    integrated web server. Integrated verification – Heartbeat Technology.
    Robust, ultra‐compact transmitter housing. Pre‐configured plug
    connector.

  • Nominal diameter range

    DN 8 to 25 (⅜ to 1″)

  • Wetted materials

    Measuring tube: 1.4435 (316L)
    Connection: 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, 
    reference density

  • Max. measurement error

    Mass flow (liquid): ±0.15 %
    Volume flow (liquid): ±0.15 %
    Mass flow (gas): ±0.75 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 18 000 kg/h (0 to 662 lb/min)

  • Max. process pressure

    350 bar (5080 psi)

  • Medium temperature range

    –50 to +150 °C (–58 to +302 °F)

  • Ambient temperature range

    –40 to +60 °C (–40 to +140 °F)
    Option: –50 to +60 °C (–58 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Compact: AlSi10Mg, coated
    Compact/ultra‐compact: 1.4301 (304)

  • Degree of protection

    IP66/67, type 4X enclosure

  • Display/Operation

    4‐line backlit display available (no local operation)
    Configuration via web browser and operating tools possible

  • Outputs

    4‐20 mA HART (active)
    Pulse/frequency/switch output (passive)

  • Inputs

    None

  • Digital communication

    HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET

  • Power supply

    DC 20 to 30 V

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, INMETRO, NEPSI

  • Product safety

    CE, C-Tick

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV Attestation)

  • Material certificates

    3.1 material

Datasheet: Proline Promass G 100 Technical Information

Shopping Cart
×