Contrec 515 Petroleum Consumption Flow Computer (FP03)

Custody transfer and fiscal measurement customers ask us for one thing above all: numbers that hold up to an audit. The Contrec 515 FP03 Petroleum Consumption Flow Computer is built for exactly that, working with dual-channel quadrature flowmeters.

The dual-channel quadrature input gives absolute signal verification, so pulse miscounts are caught rather than silently accepted, in line with ISO 6551 Level B pulse security. On top of the flow signal, it takes live temperature and density inputs and corrects volume to reference conditions in compliance with ASTM D1250-04 and ASTM-IP-API Table 54, covering crude oils, lube oils, refined products, LPG, and user-defined custom fluids. From this it computes net volume, gross volume, and mass flowrate together.

In actual application, this instrument usually sits out at a terminal or pipeline site, not in a control room, so it comes in a weather-tight enclosure with a backlit display and a tactile keypad for field use. It also has 4-20mA loop retransmission, an adjustable 8-24V DC sensor excitation supply, and dual RS-232/RS-485 Modbus RTU ports for terminal and pipeline network integration.

Before we quote this, we would normally check your flowmeter’s quadrature output, the fluid types you need to measure, and whether you need full custody-transfer grade certification or standard fiscal metering.

Hope this helps.

Contrec Model 515 FP03 Technical Specifications
● POWER SECTION
Power Supply Options115 Vac ±15% standard (Optional: 230 Vac ±15% layout via model code E)
12 to 28 Vdc external field loop power input
Transducer Power OutputAdjustable 8 to 24 Vdc sensor excitation voltage regulated via software controls; maximum continuous current capacity up to 50mA.
Memory RetentivityNon-volatile flash memory permanently stores accumulative totalizers, custom tags, and configuration data indefinitely during full power outages.
● INPUT SECTION
Flowmeter Signal InputsDual frequency channels configuration optimized to accept Quadrature Pulse Signals.
Compatible Sensors: Millivolt signals, reed switches, Namur proximity sensors, and standard open collector logic pulse trains.
Frequency Range: 0Hz minimum to 10kHz maximum high-speed processing range.
Compensation InputsAnalog Temperature Input: RTD (Pt100) or linear 4 to 20 mA process loop.
Analog Density Input: 4 to 20 mA active process loop transmitter.
● OUTPUT SECTION
Analog Retransmission LoopFully isolated 4 to 20 mA DC current loop retransmission output channel with programmable range scaling.
Digital Pulse RetransmissionOpen collector transistor output featuring software-defined volumetric scaling factor and adjustable pulse width duration.
Serial InfrastructureRS-232 Port: Connection link optimized for receipt printer attachment or local PC terminal programming.
RS-485 Port (Optional): Multi-drop serial bus supporting long-range data tracking.
Supported Protocols: Modbus RTU (Slave), standard Ticket Printer, and Contrec command-line protocols.
Local Operator InterfaceBacklit alphanumeric LCD display with language selection and custom tags. Showcases real-time parameters: Net Volume, Net Flowrate, Gross Volume, Gross Flowrate, Mass, Mass Flowrate, Temperature, and Density.
● PERFORMANCE
Calculation AccuracyBetter than ±0.01% of reading for all internal volumetric balancing algorithms, ASTM D1250-04 correction tables, and multi-fluid density lookups.
Analog Retransmission PrecisionBetter than ±0.05% of full scale range under reference conditions.
Data Logging MatrixIntegrated Real-Time Clock (RTC) logging matrix capturing over 1,000 entries for continuous process audit tracking.
● PHYSICAL
Enclosure Shell ConstructionMolded field-mounting enclosure utilizing high-rigidity impact polymers (Optional flush panel mount, pipe track mount, or deployment within a heavy Ex410 explosion-proof housing).
Tactile Input InterfaceErgonomic elastomeric tactile keypad featuring front panel adjustment control entries.
● STANDARDS CONFORMITY
Environmental SafeguardingStandard IP65 weatherproof frontal fascia shield protection.
*Note: Conformal PCB coating (Option C) is required for maximum environmental operating range and to avoid damage from moisture and corrosion.